Fuel Vent Issue

Use this area for aviation related general discussions, newsworthy items, and non model specific topics.

Fuel Vent Issue

Postby aganjoo » Sun Jun 15, 2014 10:23 pm

Hi Folks

It seems that I have a Fuel Vent issue. I was running some static RPM tests today and it was the first time that the engine has run for more than 10 minutes at a time since being installed on the airframe

The engine ran fine for the first few minutes and after that it would start and then just die a few seconds later. After playing with Carb/Mixture settings for a couple of hours and beating my head against the wall to no avail, I decided to see if it was a fuel vent issue. I loosened the fuel tank cap enough so that some air would get into the tank and tried again.

Guess what .... the engine starting running perfectly. I ran it for a long time after that without any glitches

To validate the theory, I closed the fuel tank cap tight again and the same problem popped up again. I am using a 90 deg elbow in the tank air vent hole and have a 3/16 metal brake line running down along the firewall and venting at the bottom. It is venting straight down so I am not sure if that is the issue vs having it bent forward to have some positive air pressure. I did blow air through the vent line and it does get through but requires quite a bit of pressure with the fuel tank cap closed. I don't think there is a block in the line either

Has anyone else experienced similar issues. If so how did you solve it?. I was considering using a bigger vent line but not sure if that is the right solution. I would welcome any thoughts and suggestions including ideas for venting

Best Regards
aganjoo
 
Posts: 17
Joined: Mon Oct 28, 2013 11:57 am

Re: Fuel Vent Issue

Postby MichaelFarley56 » Sun Jun 15, 2014 10:52 pm

It sounds to me like there's a blockage in your vent line somewhere. How difficult is it to blow air through the line with the fuel cap removed? That line is large enough that you shouldn't have much of an issue. Given the design of the cap and tank I'm not sure how the cap can cause interference, but if you can easily blow air through the line with no fuel cap and it's really tough with the cap there's a problem somewhere.

Is there a kink in the brake line someplace? Did you seal the elbow with TFE paste and possibly have some blocking the vent? I know it's a pain but if I were you, I'd consider removing the entinre vent line from the tank and using a compressor to blow some high pressure air through there to see if something is lodged. For obvious reasons, I don't think you're going to want to fly with that issue.
Mike Farley
Waiex #0056 - N569KM (sold)
Onex #245
MichaelFarley56
 
Posts: 1485
Joined: Thu Jun 02, 2011 11:38 pm
Location: Columbus, Ohio

Re: Fuel Vent Issue

Postby tonyr » Mon Jun 16, 2014 1:28 am

I would have thought 3/16" line was a bit small to begin with for a Corvair sucking fuel through the feed line?
Sonex #813
First Flight... 4 Oct 14
298 hours having fun!
http://sonexaus.wikispaces.com/Tony+%28Richo%29+Richardson+Sonex+813
User avatar
tonyr
 
Posts: 200
Joined: Thu Jun 27, 2013 12:50 am

Re: Fuel Vent Issue

Postby fastj22 » Mon Jun 16, 2014 9:34 am

Vent capacity can easily be verified with a flow test. Remove the fuel line from the carb and measure max flow through the system. If it exceeds 15 gallons per hour, you are fine. The corvair shouldn't need more than 8 GPH.

John Gillis
SEL Private, Comm Glider, Tow pilot (Pawnee Driver)
Waiex N116YX, Jabiru 3300, Tail dragger,
First flight, 3/16/2013. 403 hours and climbing.
Home: CO15. KOSH x 5
Flying a B-Model Conversion (Super Bee Baby!)
User avatar
fastj22
 
Posts: 1594
Joined: Sun Aug 21, 2011 5:56 pm
Location: Mile High

Re: Fuel Vent Issue

Postby aganjoo » Mon Jun 16, 2014 1:12 pm

Thanks for the responses

I will be running some additional tests as suggested above and see what I can figure out before I start replacing the vent line
aganjoo
 
Posts: 17
Joined: Mon Oct 28, 2013 11:57 am

Re: Fuel Vent Issue

Postby n502pd » Mon Jun 16, 2014 8:59 pm

When I did my vent line reecently, I looked at the size of specified tubing. I thought it might be a bit small, so I used 3/8 diameter, and hope I dont have any problems like yours. Remember the vent line takes air into the tank as fuel is removed by the engine, and there should be no pressure difference fro outsid air to inside tank air (or very very little difference). If there is any measurable difference then you are actually pulling a vacume on the tank, and less fuel will flow out to the engine. At least that is how I view this process. I have also beveled the bottom end and bent forward a slight bit to have a bit of ram air effect, and be sure it is below the bottom edge of the coweling and in the slipstream. :)
Joe Nelsen
scratch built :D
Sirpeedee, N502PD, s/n 1510, Aero Vee 2.1 s/n 0870,
ADS-B in (Stratux)/out(SkyBeacon)
Flying @81.7
KGYI/N. Tx Reg/Perrin Field
EAA Technical Counselor, Chapter 323, Sherman, TX
User avatar
n502pd
 
Posts: 380
Joined: Sat Feb 23, 2013 12:13 am
Location: Gunter, Texas

Re: Fuel Vent Issue

Postby tonyr » Mon Jun 16, 2014 10:12 pm

A local flyer here has a top mounted forward facing 3/8" vent, no issues with pressurization or vacuum lock... but does attract the larger species of mud-dauber wasp :D
Sonex #813
First Flight... 4 Oct 14
298 hours having fun!
http://sonexaus.wikispaces.com/Tony+%28Richo%29+Richardson+Sonex+813
User avatar
tonyr
 
Posts: 200
Joined: Thu Jun 27, 2013 12:50 am

Re: Fuel Vent Issue

Postby n502pd » Mon Jun 16, 2014 10:30 pm

I had tholught about the upper vent also, and maybe it is better since there is less pipe involved. But, I was/am worried about roll-over tank drainage, as in flipping over on the top durring a botched landing, or something. Just what I decided to do was take the vent out the bottom. Others may feel different. let us know what happens to fix your porblem, for sure! :)
Joe Nelsen
scratch built :D
Sirpeedee, N502PD, s/n 1510, Aero Vee 2.1 s/n 0870,
ADS-B in (Stratux)/out(SkyBeacon)
Flying @81.7
KGYI/N. Tx Reg/Perrin Field
EAA Technical Counselor, Chapter 323, Sherman, TX
User avatar
n502pd
 
Posts: 380
Joined: Sat Feb 23, 2013 12:13 am
Location: Gunter, Texas

Re: Fuel Vent Issue

Postby rizzz » Tue Jun 17, 2014 12:52 am

tonyr wrote:A local flyer here has a top mounted forward facing 3/8" vent, no issues with pressurization or vacuum lock... but does attract the larger species of mud-dauber wasp :D

No kidding.
Adrian Clout had an engine failure followed by a forced landing, guess what caused it?
Wasp nest in his fuel vent tube.
He was able to make it to pattern altitude when the engine quit.

Anyway, here’s what I plan to do:
Image
Michael
Sonex #145 from scratch (mostly)
Taildragger, 2.4L VW engine, AeroInjector, Prince 54x48 P-Tip
VH-MND, CofA issued 2nd of November 2015
First flight 7th of November 2015
Phase I Completed, 11th of February 2016
http://www.mykitlog.com/rizzz/
rizzz
 
Posts: 869
Joined: Tue Jun 21, 2011 2:07 am
Location: Wollongong, NSW, Australia

Re: Fuel Vent Issue

Postby fastj22 » Tue Jun 17, 2014 12:59 am

If you vent like that from the top, and you ever go inverted, you will spray fuel over your windscreen.

John Gillis
SEL Private, Comm Glider, Tow pilot (Pawnee Driver)
Waiex N116YX, Jabiru 3300, Tail dragger,
First flight, 3/16/2013. 403 hours and climbing.
Home: CO15. KOSH x 5
Flying a B-Model Conversion (Super Bee Baby!)
User avatar
fastj22
 
Posts: 1594
Joined: Sun Aug 21, 2011 5:56 pm
Location: Mile High

Next

Return to General Discussion

Who is online

Users browsing this forum: Bing [Bot] and 0 guests