by peter anson » Fri Aug 12, 2016 6:14 am
Hi Phil,
I have the fuel flow sender supplied by the Australian agent for MGL but the procedure should be the same. I ran fuel through the sender into a measuring container over say, 5 minutes to get the fuel flow rate, then converted it to litres per hour. While the fuel was running I read the flow rate indicated by the Ultra Horizon and then got a ratio of indicated flow/real flow. According to the manual the K factor is the number of pulses per litre, so you would multiply the existing K factor by the ratio you have calculated.
For example, if your indicated fuel flow is 30 litres per hour but your measured flow is 20 litres per hour, the ratio is 1.5
Multiply the K factor by 1.5, so 1.5 x 7000 = 10500
Change the K factor to 10500 and retest. It should be correct or at least much closer to the correct value, and you can repeat the procedure.
Now bearing in mind that I did all this about 4 1/2 years ago and I have lost many brain cells since then, I may be wrong, but I do recall measuring flow rates at least. It's one of those jobs where it would be good to have two people, oh, and a fire extinguisher.
Peter