NACA vents

Use this area for aviation related general discussions, newsworthy items, and non model specific topics.

NACA vents

Postby 1planeguy » Wed Feb 25, 2015 4:32 pm

Seems I remember reading on a builder page that most builders are using the Vans's NACA vent parts?...the SV-1?

Also wondering if someone could pass on the info to help locate it properly...about to cut out side skins and would like to cut the holes for it now...

Jeremy
Plans #410
1planeguy
 
Posts: 8
Joined: Sat Mar 29, 2014 1:17 pm

Re: NACA vents

Postby gammaxy » Wed Feb 25, 2015 9:16 pm

Unless you really like the look of the NACA vents, I recommend using these rectangular vents from Vans instead.

https://www.vansaircraft.com/cgi-bin/st ... 10vent_kit

When you don't need them they close pretty nice. When you need them, little beats a flap scooping 120+mph wind directly into the cockpit.
Chris Madsen
Aerovee Sonex N256CM
Flying since September 2014
Build log: http://chrismadsen.org
gammaxy
 
Posts: 601
Joined: Wed Sep 04, 2013 9:31 am

Re: NACA vents

Postby kmacht » Wed Feb 25, 2015 9:59 pm

I'll second the recommendation for the Vans door vents instead of the NACA vents. They are cheap, super simple to install and very effective. A bonus is that they are pretty close to waterproof when closed. I tie my sonex down outside and have never seen water get in from those vents.

Keith
#554
kmacht
 
Posts: 772
Joined: Tue Jun 21, 2011 11:30 am

Postby 1planeguy » Wed Feb 25, 2015 10:29 pm

Guess my only reservation would be can you control where the air blows? Biggest thing I liked about the other vents was the eyeball vents attached to them that could be pointed...hate air blowing in my eyes...etc.
If I went with the simple door type did you still install them in the same place?
1planeguy
 
Posts: 8
Joined: Sat Mar 29, 2014 1:17 pm

Re: NACA vents

Postby gammaxy » Wed Feb 25, 2015 11:08 pm

Here's where I installed mine:

Image

As with anything that's not spelled out in the plans, I spent a few hours figuring out exactly where to put them, but it probably doesn't matter much. I wanted them to be low enough to not be blowing directly on the back of the panel, close enough to reach without too much trouble (I probably have to loosen a shoulder strap to reach the far one), and far enough to give the air a chance to circulate somewhat.

With these doors, you can't really control where the air blows, but you probably don't have to worry about air blowing directly in your eyes :-)

I feel like people with the NACA vents and tubing and eyeball vents end up restricting the airflow to the point that they need to add scoops or windshield vents. I haven't flown in the mid-upper 90s yet, but one vent has always been enough to keep me comfortable.
Chris Madsen
Aerovee Sonex N256CM
Flying since September 2014
Build log: http://chrismadsen.org
gammaxy
 
Posts: 601
Joined: Wed Sep 04, 2013 9:31 am

Postby 1planeguy » Thu Feb 26, 2015 11:36 am

Thankfully there isn't much not spelled out in the plans...
1planeguy
 
Posts: 8
Joined: Sat Mar 29, 2014 1:17 pm


Return to General Discussion

Who is online

Users browsing this forum: No registered users and 64 guests