Princeton fuel probe having zero ohms output

Discussion of aircraft electrical system design, construction, and problems.

Princeton fuel probe having zero ohms output

Postby phenry » Sat Dec 06, 2014 7:54 pm

I have a problem with my Princeton fuel probe which is connected to an mgl ultra panel.
When I try to calibrate the fuel level the output from the probe does not change as fuel is added to the tank, it stays constantly at zero ohms. Has any body seen this issue before?
Peter Henry
W#149
User avatar
phenry
 
Posts: 60
Joined: Tue Nov 22, 2011 11:29 pm
Location: Newborough Vic. Australia

Re: Princeton fuel probe having zero ohms output

Postby gammaxy » Sat Dec 06, 2014 10:59 pm

Have you checked that the fuel level "pull up" dip switch on your RDAC is set correctly?
Chris Madsen
Aerovee Sonex N256CM
Flying since September 2014
Build log: http://chrismadsen.org
gammaxy
 
Posts: 600
Joined: Wed Sep 04, 2013 9:31 am

Re: Princeton fuel probe having zero ohms output

Postby daleandee » Sun Dec 07, 2014 12:36 am

*
Last edited by daleandee on Fri Jun 10, 2016 3:26 pm, edited 1 time in total.
User avatar
daleandee
 
Posts: 877
Joined: Fri Feb 01, 2013 6:14 pm

Re: Princeton fuel probe having zero ohms output

Postby peter anson » Sat Dec 27, 2014 7:21 am

Hi Peter, just in case you haven't solved this one yet - I also had trouble with my Princeton probe. It was a while back so I can't remember what the output was but it didn't change when I added fuel. Princeton were very good to deal with. They sent me a replacement which solved all the problems - well, except for the fuel leak that developed from the tank fitting which took another month to plug.
See http://sonexaus.wikispaces.com/Peter+Anson+-+Sonex+894

Peter Anson
Sonex 894
185 hours
peter anson
 
Posts: 558
Joined: Thu Jul 31, 2014 2:34 am
Location: Mount Macedon, Australia


Return to Electrical System

Who is online